Frame Sizes -
0.25kw 4 pole, 0.37kw 4 pole = 71 frame shaft size 14 x 30, (B3 foot mounted, base to centre height 71, footprint 112w x 90, overall length 250.5) (B5 flange mounted 160 dia, 4 x boltholes on 130 PCD, spiggot 110) (B14 'C' face mounted 105 dia, 4 tapped holes on 85 PCD, spiggot 70)
0.55kw 4 pole, 0.75kw 4 pole = 80 frame shaft size 19 x40, (B3 foot mounted, base to centre height 80, footprint 125w x 100, overall length 278.5) (B5 flange mounted 200 dia, 4 x boltholes on 165 PCD, spiggot 130) (B14 'C' face mounted 120 dia, 4 tapped holes on 100 PCD, spiggot 80)
1.1kw 4 pole = 90S frame shaft size 24 x 50, (B3 foot mounted, base to centre height 90, footprint 140w x 100, overall length 310) (B5 flange mounted 200 dia, 4 x boltholes on 165 PCD, spiggot 130) (B14 'C' face mounted 140 dia, 4 tapped holes on 115 PCD, spiggot 95)
1.5kw 4 pole, 2.2kw 2 pole = 90L frame shaft size 24 x 50, (B3 foot mounted, base to centre height 90, footprint 140w x 125, overall length 325) (B5 flange mounted 200 dia, 4 x boltholes on 165 PCD, spiggot 130) (B14 'C' face mounted 140 dia, 4 tapped holes on 115 PCD, spiggot 95)
2.2kw 4 pole, 3 kw 4 pole, 3 kw 2 pole = 100 frame shaft size 28 x 60, (B3 foot mounted, base to centre height 100, footprint 160w x 140, overall length 370) (B5 flange mounted 250 dia, 4 x boltholes on 215 PCD, spiggot 180) (B14 'C' face mounted 160 dia, 4 tapped holes on 130 PCD, spiggot 110)
All output shafts are fitted with a standard key. All single phase motors can be in either direction permanently, e.g. for a compressor,or wired to run in both directions as would be required for a garage door operator or similar.